SC90Ea
Cavity + Inner Max 235mm
Any variation of design available |
 |
Optional Features |
Lintray |
Prefix L |
Feature Brick |
Suffix/FB |
Step 20mm |
Suffix/ST |
Flat Base |
Suffix/F |
Cant Outer 50mm |
Suffix/C |
Wide Outer 125mm |
Suffix/WO |
|
Lintels Properties |
Ixx cm4 |
299.19 |
Zxx cm3 |
32.17 |
Weight kg/m |
13.52 |
Area cm2 |
17.20 |
Ryy cm |
6.87 |
|
Opening
Size |
Lintel
Lengh |
Safe UDL kN Load Ratio 1:5 |
600 |
900 |
30 |
750 |
1050 |
30 |
900 |
1200 |
30 |
1050 |
1350 |
30 |
1200 |
1500 |
28 |
1350 |
1650 |
26 |
1500 |
1800 |
23 |
1650 |
1950 |
21 |
1800 |
2100 |
20 |
1950 |
2250 |
18 |
2100 |
2400 |
17 |
2250 |
2550 |
16 |
2400 |
2700 |
15 |
2550 |
2850 |
14 |
2700 |
3000 |
- |
2850 |
3150 |
- |
3000 |
3300 |
- |
3150 |
3450 |
- |
3300 |
3600 |
- |
3450 |
3750 |
- |
3600 |
3900 |
- |
3750 |
4050 |
- |
3900 |
4200 |
- |
4050 |
4350 |
- |
4200 |
4500 |
- |
4350 |
4650 |
- |
4500 |
4800 |
- |
|
|
|
 |
SC90Eb
Cavity + Inner Max 235mm
Any variation of design available |
 |
Optional Features |
Lintray |
Prefix L |
Feature Brick |
Suffix/FB |
Step 20mm |
Suffix/ST |
Flat Base |
Suffix/F |
Cant Outer 50mm |
Suffix/C |
Wide Outer 125mm |
Suffix/WO |
|
Lintels Properties |
Ixx cm4 |
921.30 |
Zxx cm3 |
68.78 |
Weight kg/m |
17.10 |
Area cm2 |
21.77 |
Ryy cm |
6.21 |
|
Opening
Size |
Lintel
Lengh |
Safe UDL kN Load Ratio 1:5 |
600 |
900 |
50 |
750 |
1050 |
50 |
900 |
1200 |
50 |
1050 |
1350 |
50 |
1200 |
1500 |
50 |
1350 |
1650 |
50 |
1500 |
1800 |
50 |
1650 |
1950 |
46 |
1800 |
2100 |
43 |
1950 |
2250 |
40 |
2100 |
2400 |
37 |
2250 |
2550 |
35 |
2400 |
2700 |
33 |
2550 |
2850 |
31 |
2700 |
3000 |
30 |
2850 |
3150 |
28 |
3000 |
3300 |
27 |
3150 |
3450 |
26 |
3300 |
3600 |
24 |
3450 |
3750 |
23 |
3600 |
3900 |
23 |
3750 |
4050 |
22 |
3900 |
4200 |
21 |
4050 |
4350 |
20 |
4200 |
4500 |
19 |
4350 |
4650 |
19 |
4500 |
4800 |
18 |
|
|
|
 |
MC90Ea
Cavity + Inner Max 235mm
Any variation of design available |
 |
Optional Features |
Lintray |
Prefix L |
Feature Brick |
Suffix/FB |
Step 20mm |
Suffix/ST |
Flat Base |
Suffix/F |
Cant Outer 50mm |
Suffix/C |
Wide Outer 125mm |
Suffix/WO |
|
Lintels Properties |
Ixx cm4 |
785.95 |
Zxx cm3 |
78.30 |
Weight kg/m |
16.97 |
Area cm2 |
21.60 |
Ryy cm |
6.27 |
|
Opening
Size |
Lintel
Lengh |
Safe UDL kN Load Ratio 1:19 |
600 |
900 |
40 |
750 |
1050 |
40 |
900 |
1200 |
40 |
1050 |
1350 |
40 |
1200 |
1500 |
40 |
1350 |
1650 |
40 |
1500 |
1800 |
40 |
1650 |
1950 |
40 |
1800 |
2100 |
40 |
1950 |
2250 |
40 |
2100 |
2400 |
40 |
2250 |
2550 |
40 |
2400 |
2700 |
38 |
2550 |
2850 |
36 |
2700 |
3000 |
34 |
2850 |
3150 |
32 |
3000 |
3300 |
31 |
3150 |
3450 |
29 |
3300 |
3600 |
28 |
3450 |
3750 |
26 |
3600 |
3900 |
24 |
3750 |
4050 |
22 |
3900 |
4200 |
20 |
4050 |
4350 |
19 |
4200 |
4500 |
18 |
4350 |
4650 |
16 |
4500 |
4800 |
15 |
|
|
|
 |
MC90Eb
Cavity + Inner Max 235mm
Any variation of design available |
 |
Optional Features |
Lintray |
Prefix L |
Feature Brick |
Suffix/FB |
Step 20mm |
Suffix/ST |
Flat Base |
Suffix/F |
Cant Outer 50mm |
Suffix/C |
Wide Outer 125mm |
Suffix/WO |
|
Lintels Properties |
Ixx cm4 |
2073.51 |
Zxx cm3 |
148.11 |
Weight kg/m |
21.35 |
Area cm2 |
27.18 |
Ryy cm |
5.76 |
|
Opening
Size |
Lintel
Lengh |
Safe UDL kN Load Ratio 1:19 |
600 |
900 |
60 |
750 |
1050 |
60 |
900 |
1200 |
60 |
1050 |
1350 |
60 |
1200 |
1500 |
60 |
1350 |
1650 |
60 |
1500 |
1800 |
60 |
1650 |
1950 |
60 |
1800 |
2100 |
60 |
1950 |
2250 |
60 |
2100 |
2400 |
60 |
2250 |
2550 |
60 |
2400 |
2700 |
60 |
2550 |
2850 |
58 |
2700 |
3000 |
55 |
2850 |
3150 |
52 |
3000 |
3300 |
50 |
3150 |
3450 |
47 |
3300 |
3600 |
45 |
3450 |
3750 |
43 |
3600 |
3900 |
42 |
3750 |
4050 |
40 |
3900 |
4200 |
39 |
4050 |
4350 |
37 |
4200 |
4500 |
36 |
4350 |
4650 |
35 |
4500 |
4800 |
34 |
|
|
|