SC125Ea
Cavity + Inner Max 270mm
Any variation of design available |
 |
Optional Features |
Lintray |
Prefix L |
Feature Brick |
Suffix/FB |
Step 20mm |
Suffix/ST |
Flat Base |
Suffix/F |
Cant Outer 50mm |
Suffix/C |
Wide Outer 125mm |
Suffix/WO |
|
Lintels Properties |
Ixx cm4 |
457.50 |
Zxx cm3 |
43.78 |
Weight kg/m |
15.21 |
Area cm2 |
19.36 |
Ryy cm |
8.08 |
|
Opening
Size |
Lintel
Lengh |
Safe UDL kN Load Ratio 1:5 |
600 |
900 |
35 |
750 |
1050 |
35 |
900 |
1200 |
35 |
1050 |
1350 |
35 |
1200 |
1500 |
35 |
1350 |
1650 |
35 |
1500 |
1800 |
35 |
1650 |
1950 |
35 |
1800 |
2100 |
32 |
1950 |
2250 |
30 |
2100 |
2400 |
28 |
2250 |
2550 |
26 |
2400 |
2700 |
24 |
2550 |
2850 |
23 |
2700 |
3000 |
- |
2850 |
3150 |
- |
3000 |
3300 |
- |
3150 |
3450 |
- |
3300 |
3600 |
- |
3450 |
3750 |
- |
3600 |
3900 |
- |
3750 |
4050 |
- |
3900 |
4200 |
- |
4050 |
4350 |
- |
4200 |
4500 |
- |
4350 |
4650 |
- |
4500 |
4800 |
- |
|
|
|
 |
SC125Eb
Cavity + Inner Max 270mm
Any variation of design available |
 |
Optional Features |
Lintray |
Prefix L |
Feature Brick |
Suffix/FB |
Step 20mm |
Suffix/ST |
Flat Base |
Suffix/F |
Cant Outer 50mm |
Suffix/C |
Wide Outer 125mm |
Suffix/WO |
|
Lintels Properties |
Ixx cm4 |
1163.28 |
Zxx cm3 |
76.75 |
Weight kg/m |
18.18 |
Area cm2 |
23.14 |
Ryy cm |
7.87 |
|
Opening
Size |
Lintel
Lengh |
Safe UDL kN Load Ratio 1:5 |
600 |
900 |
56 |
750 |
1050 |
56 |
900 |
1200 |
56 |
1050 |
1350 |
56 |
1200 |
1500 |
56 |
1350 |
1650 |
56 |
1500 |
1800 |
56 |
1650 |
1950 |
56 |
1800 |
2100 |
56 |
1950 |
2250 |
52 |
2100 |
2400 |
49 |
2250 |
2550 |
46 |
2400 |
2700 |
43 |
2550 |
2850 |
40 |
2700 |
3000 |
38 |
2850 |
3150 |
36 |
3000 |
3300 |
35 |
3150 |
3450 |
33 |
3300 |
3600 |
32 |
3450 |
3750 |
30 |
3600 |
3900 |
29 |
3750 |
4050 |
28 |
3900 |
4200 |
27 |
4050 |
4350 |
26 |
4200 |
4500 |
25 |
4350 |
4650 |
24 |
4500 |
4800 |
23 |
|
|
|
 |
MC125Ea
Cavity + Inner Max 270mm
Any variation of design available |
 |
Optional Features |
Lintray |
Prefix L |
Feature Brick |
Suffix/FB |
Step 20mm |
Suffix/ST |
Flat Base |
Suffix/F |
Cant Outer 50mm |
Suffix/C |
Wide Outer 125mm |
Suffix/WO |
|
Lintels Properties |
Ixx cm4 |
812.99 |
Zxx cm3 |
86.30 |
Weight kg/m |
18.06 |
Area cm2 |
22.99 |
Ryy cm |
7.88 |
|
Opening
Size |
Lintel
Lengh |
Safe UDL kN Load Ratio 1:19 |
600 |
900 |
50 |
750 |
1050 |
50 |
900 |
1200 |
50 |
1050 |
1350 |
50 |
1200 |
1500 |
50 |
1350 |
1650 |
50 |
1500 |
1800 |
50 |
1650 |
1950 |
50 |
1800 |
2100 |
50 |
1950 |
2250 |
50 |
2100 |
2400 |
50 |
2250 |
2550 |
50 |
2400 |
2700 |
48 |
2550 |
2850 |
46 |
2700 |
3000 |
43 |
2850 |
3150 |
40 |
3000 |
3300 |
36 |
3150 |
3450 |
33 |
3300 |
3600 |
30 |
3450 |
3750 |
28 |
3600 |
3900 |
25 |
3750 |
4050 |
23 |
3900 |
4200 |
22 |
4050 |
4350 |
20 |
4200 |
4500 |
19 |
4350 |
4650 |
17 |
4500 |
4800 |
16 |
|
|
|
 |
MC125Eb
Cavity + Inner Max 270mm
Any variation of design available |
 |
Optional Features |
Lintray |
Prefix L |
Feature Brick |
Suffix/FB |
Step 20mm |
Suffix/ST |
Flat Base |
Suffix/F |
Cant Outer 50mm |
Suffix/C |
Wide Outer 125mm |
Suffix/WO |
|
Lintels Properties |
Ixx cm4 |
1941.35 |
Zxx cm3 |
142.71 |
Weight kg/m |
21.24 |
Area cm2 |
27.03 |
Ryy cm |
7.73 |
|
Opening
Size |
Lintel
Lengh |
Safe UDL kN Load Ratio 1:19 |
600 |
900 |
70 |
750 |
1050 |
70 |
900 |
1200 |
70 |
1050 |
1350 |
70 |
1200 |
1500 |
70 |
1350 |
1650 |
70 |
1500 |
1800 |
70 |
1650 |
1950 |
70 |
1800 |
2100 |
70 |
1950 |
2250 |
70 |
2100 |
2400 |
70 |
2250 |
2550 |
70 |
2400 |
2700 |
70 |
2550 |
2850 |
70 |
2700 |
3000 |
70 |
2850 |
3150 |
68 |
3000 |
3300 |
65 |
3150 |
3450 |
62 |
3300 |
3600 |
59 |
3450 |
3750 |
57 |
3600 |
3900 |
54 |
3750 |
4050 |
52 |
3900 |
4200 |
50 |
4050 |
4350 |
48 |
4200 |
4500 |
45 |
4350 |
4650 |
42 |
4500 |
4800 |
40 |
|
|
|